AMBER Archive (2002)Subject: Re: Density during equilibration (sander)
From: Pratul Agarwal (pratulka_at_rocketmail.com)
Date: Thu Sep 26 2002 - 09:09:02 CDT
This is mainly for the archives.
I found the source of the problem and a fix. The problem was with
performing the constant pressure MD with restraints on the solute
atoms. To get the final density closer to 1.0 g/cc, I decided to
perform an additional small time period constant pressure MD after all
the steps of equilibration (when all restraints on the solute atoms
have been gradually removed).
--- Pratul Agarwal <pratulka_at_rocketmail.com> wrote:
> The density of my simulation box (protein in TIP3P box) stabilizes
> around 0.90-0.94 during NPT simulation and does not reach close to
> 1.0.
> (I have tried different values of taup 0.2-1.0ps and my simulation
> length is 30ps.) Has anybody seen this problem before? I would
> appreciate any comments/suggestions.
>
> I have tried reducing the box dimensions in the crd file (as
> suggested
> by the GIBBS tutorial), and then the density reaches 1.0 very
> quickly.
> I was wondering if I need to follow any special set of instructions
> while doing this and if by manually decreasing the box size I would
> introduce any artificial forces/changes in the system.
>
> __________________________________________________
> Do you Yahoo!?
> Yahoo! News - Today's headlines
> http://news.yahoo.com
>
__________________________________________________
Do you Yahoo!?
New DSL Internet Access from SBC & Yahoo!
http://sbc.yahoo.com
|