AMBER Archive (1999)Subject: Re: distance restraint and ibelly
From: David Pearlman (David_Pearlman_at_vpharm.com)
on 11/17/99 8:35 AM, Nancy Bourassa wrote:
As always, you can void the trickiness of order dependence when doing
The Interface script below gives an example that includes a belly,
If you insist on NOT using the Interface front end, then simply run
dap
sander
title = "generic title"
steps = 10000/runs=10
timestep = 0.0010
! set up the belly. Allow residues 1-110 to move
belly
! Use shake; Use standard temp. coupling with a single scale factor
shake/toler=0.0005
! ramp up the temperature in the early stages, then hold at 300K
change TEMP0 /from= 10.0/to= 300.0 /step1= 0/step2= 5000/every=5
! Set up the distance restraint between atoms C1 in residues 1 and 2:
restraint /at1=1:C1 /at2=2:C1 \
! read restraints from file restraints.list
nmr /disang = "restraints.list" /listout = "restraints.final"
generate /namelist /output=md1.inp
--------------------------------------------------------------------------
-- David A. Pearlman email: dap_at_vpharm.com Vertex Pharmaceuticals Inc. 130 Waverly St. "There are only 25 great people in the world & Cambridge, MA 02139-4242 5 of them are hamburgers..." -- Cptn Beefheart
| |||||||||||||||||||||||||||||||||
|