AMBER Archive (2005)Subject: Re: AMBER: using position restraints in target MD?
From: Viktor Hornak (hornak_at_csb.sunysb.edu)
Date: Fri Oct 21 2005 - 15:14:42 CDT
Dear Ben,
As you're obviously using Amber8, you can use positional restraints as
usually, with ntr=1 and restraint mask and weight set...
Cheers,
-Viktor
Ben-Zhuo Lu wrote:
> Dear Amber users,
> I'm wondering if we can use position restrains in the
> the target MD simulation. In TMD, both the parts defined by tgtfitmask
> and tgtrmsmask will be affected, but sometimes, we want to keep
> most part (not the masked part by tgtrmsmask) of the simulated system
> stable.
> Then, how to do it?
>
> Thanks,
>
> Ben.
>
> -----------------------------------------------------------------------
> The AMBER Mail Reflector
> To post, send mail to amber_at_scripps.edu
> To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
--
===================================================================
Viktor Hornak