Subject: Re: AMBER: sander error

From: Guanglei Cui (cuigl_at_csb.sunysb.edu)
Date: Mon Oct 10 2005 - 08:52:29 CDT


Hi,

It's probably some error in your prmtop file. If you're doing truncated
octahedron PBC (ifbox = 2), check the last line of your restrt file (box
info). They probably don't match each other.

Guanglei

Yam wrote:
> Dear all,
>
> I encounter this problem when I run sander for water
> relaxation,
>
> Error: ifbox=2 in prmtop but angles are not correct
>
> *** input error(s)
>
> Anyone encounter this problem before? Please help.
>
> regards,
> Yam
>
>
>
>