AMBER Archive (2000)

Subject: Re: dielectric constant

From: Soaring Bear (bear_at_dakotacom.net)
Date: Sat Aug 19 2000 - 10:03:43 CDT


There is a whole body of literature on this question.
You might start with:

Daggett V. Kollman PA. Kuntz ID. Molecular dynamics simulations of small
peptides: dependence on dielectric model and pH. Biopolymers 31:285-304
1991

Soaring Bear Ph.D. Research Pharmacologist
Scientific advisor to the health professions
http://soaringbear.com
soaringbear_at_yahoo.com

--
HERBMED is Science Mag. hotpick for June 23, 2000
http://www.sciencemag.org/cgi/content/summary/288/5474/2091b
http://www.amfoundation.org/herbmed.htm

----- Original Message ----- From: David Small <David.Small_at_hec.utah.edu> To: <amber_at_cgl.ucsf.edu> Sent: Thursday, August 17, 2000 12:10 PM Subject: dielectric constant

> > Hi, > > I've been doing simulations (sander, gibbs) with the default > dielectric constant of 1 (DIELC = 1). I've read that the dc of water is > around 78, and being that my system is solvated in water, running with a > DC of 1 would produce incorrect results (I have seen quite varied > results as I alter DIELC). If I don't already have the correct DC from > data, how would I find an representative value to use? > > thanks, > > dave > >